2.1 Wiring Detail – Garden Style Cabinet
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date: Rev.Dwg. No.
B
Main / Garden Style Cabinet
Board Layout
M1816-065-44/05
1816 Telephone Intercom System
Wiring Detail - Garden Style Control Cabinet
17 21151413 20191811 12 16 23 2422
INCOMING
C.O. PHN
LINES
C.O.
PHN
16 VAC
PWR
INPUT
Lobby Panel
3
1
2
5
8
Resident
Telephone
9
10
11
16 Volt, 40 VA UL Listed Transformer.
1
2
Earth Ground.
3
Optional Central Office phone line - touch tone, loop start.
4
Doorman Telephone (Optional).
5
Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for
additional wiring requirements.
6
Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.
7
Decoder board terminals. Use only if more than 5 relay boards are
connected to system. See drawing M1816-065-5.
9
Incoming phone lines from Central Office.
10
Outgoing phone lines to individual apartments.
11
DoorKing connecting cable.
7
8
RJ71C phone block. See drawing M1816-065-6 for detail.
Doorman Telephone
4
4312
6
6