Doorking 6500 User Manual Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
31
6500-065-K-7-08
6.1 Maintenance
SECTION 6 - MAINTENANCE AND TROUBLESHOOTING
Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or
suspected. High cycle usage may require more frequent service checks.
When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper
operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can
be identified and corrected.
Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be
made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping
this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result
in serious injury or death should they become entrapped in the gate.
When servicing this gate operator, always turn power OFF!!
If gearbox requires oil, use only SYNTHETIC SHC-629 Oil. Do not completely fill gearbox with oil. Gearbox should be half
full only. Do not exceed this level.
Operator
Component
Maintenance
Monthly Interval
6312
Alarm
Arms
Batteries
DC Open System
Drive Belt
Fire Dept.
Gate
Loop(s)
Release
Primary Reverse System
Secondary Reverse Device
Complete System
Activate the primary (inherent) reverse system by blocking the
gate with a solid object. When the gate reverses, block the gate
in the opposite direction prior to the limit being reached. The
entrapment alarm should activate. Press the reset button to
silence the alarm.
If operator is equipped with optional DC open system, check the
batteries for any leakage or loose connections. Batteries should
be replaced every two years.
Check set screws and nuts. Check bushings for wear.
Check for alignment, tightness and wear.
Check vehicular reverse and shadow loops for proper operation.
Check manual release for proper operation.
Complete check of gate and gate operating system.
Check emergency vehicle access device for proper operation.
If operator is equipped with optional DC open system, check to
be sure the system opens the gate upon loss of AC power.
Inspect for damage. Check gate hinges for wear and grease if
necessary.
Check that the gate reverses on contact with an object in both
the opening and closing cycles.
Adjust the reversing sensor if necessary.
Check secondary (external) reverse device(s) stop or reverse the
gate when activated.
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 47 48

Comments to this Manuals

No comments