3.2 DIP-Switch Settings
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
Switch 1 Sets direction of the primary operator so that the operator cycles open upon initial power up and open command. If the
operator begins to cycle close upon initial power up and open command, turn power off and change the setting on this switch.
Switch 2 Sets direction of the secondary operator so that the operator cycles open upon initial power up and open command. If
the operator begins to cycle close upon initial power up and open command, turn power off and change the setting on this
switch.
Switch 3 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT port will be sent
directly to the microprocessor to open the gate, or if the output is directed to Terminal 4 where it can then be connected to other
input terminals.
Switch 4 Turns the auto close timer on or off. Maximum time that the close timer can be set for is approximately 23 seconds.
Switch 5 This switch sets the input at Terminal 6 to act as a normal reverse input or to act as a shadow input. A shadow input
will only hold the gate operator in the open position once it is in the full open position. A shadow input will not reverse the
direction of the gate operator once it begins its close cycle.
Switch 6 Sets up the circuit board for single or primary / secondary (dual) gate operation.
Switches 7-8 These work in conjunction with each other and determine when the relay on the board will be activated. This relay
can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a
green light when the gate is full open. This relay is not available for these uses if it is being used for the shadow loop function.
Switch 1 Used in primary / secondary applications, turning this switch ON will cause the start of the primary operator to be
delayed 1-2 seconds. This allows the secondary gate to reach the full closed position prior to the primary gate, which is
desirable when the gates are constructed with an overlap or if a magnetic lock is used to secure the gates.
Switch 2 If a magnetic lock is not used with the gate operator, leave this switch in the OFF position. Turn this switch ON if a
magnetic lock is used and connected to Terminals 9 and 12. This applies magnetic lock power and logic to these terminals.
Switch 3 Spare switch, not used. Leave in OFF position.
Switch 4 Spare switch, not used. Leave in OFF position.
Switch Function Setting Description
SW 1 (Top 8 Switches)
Primary
Secondary
Open loop
Logic Output
OFF
ON
OFF
ON
OFF
ON
OFF
ON
7-OFF
7-OFF
7-ON
7-ON
8-OFF
8-ON
8-OFF
8-ON
Auto-Close
Timer
Reverse Loop
Shadow Loop
Single Operator
Dual Operators
Relay
1
2
3
4
5
6
7 and 8
Direction-operator should cycle open upon initial power up and open command.
Direction-operator should cycle open upon initial power up and open command.
Terminal 4 is the output from the open detector.
Terminal 4 is an open input.
Auto-close timer is OFF. Manual input required to close gate.
Auto=close timer is ON. Adjustable from 1-23 seconds.
Terminal 6 is a Reverse input.
Terminal 6 is a Shadow input.
Switch must be OFF for single operator.
Switch must be ON when bi-parting (dual) gates are used.
Relay activates when gate is open.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates when gate is opening and closing.
Switch Function Setting Description
SW 2 (Bottom 4 Switches)
Spare
Spare
Not Used
Not Used
Gate Overlap
OFF
ON
OFF
ON
Magnetic lock
1
2
3
4
Primary and secondary operators start at the same time.
Secondary operator starts 1-2 seconds prior to the primary operator.
Magnetic lock is not used.
Magnetic lock is used and connected to terminals 9 and 12.
6500-065-K-7-08