2.2 Wiring Diagram
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date: Rev.Dwg. No.
PWR
INPUT
1
Phone
Line
5
6
4
7
1
2
NO NC COM
MAIN TERMINAL
RELAY 2 CONTACTS
SWITCH 2
INPUT
Strike /
Mag Lck
Gate
Operator
Lock
Pwr
32
Gate
Operator
Strike /
Mag Lck
Lock
Pwr
23
Field Wire Diagram - 1862 Control Board
8/06
B
M1800-065-11
Phone Line Wiring Max Distance
800 Feet
1600 Feet
24 AWG
22 AWG
Power Wiring Max Distance
100 Feet
200 Feet
18 AWG
16 AWG
16 Volt, 20 VA UL Listed power transformer.
1
2
Power for door strikes or magnetic lock is not provided by the
system. It must be provided by an external power supply.
3
Electric strikes are wired to Normally Open (N.O.) contacts; magnetic
locks are wired to the Normally Closed (N.C.) contacts.
4
Optional 12 Volt gel cell for backup power.
5
Dedicated Central Office (C.O.) phone line - touch tone, loop start.
6
A switch closure across terminals 4 & 8 will activate relay 1 for its programmed
strike time. This is where the postal switch is prewired.
7
A switch closure across these terminals will activate relay 2 for its programmed strike
time or cause the system to dial a preprogrammed phone number. See 3.1.6.
All wiring to be performed in accordance with National Electric Code.
10 11 12 13 14198765432
1862-010
Circuit Board
Field Wire Diagram - 1862-010 Control Board
Earth
Ground
8
Display must be removed to access these terminals (1802-EPD models only).
8
1802-065-E-5-10 Page 19