4.2 Technician Commands
The following commands should be used by trained technicians only and are designed for trouble
shooting purposes.
4.2.1 Reset Main Control Board
This programming sequence will reset the 1885 main control board to the factory default values. This
function will take about 5 minutes to complete.
1. Take the doorman telephone off hook.
2. Press *91 and enter the four-digit MASTER CODE _ _ _ _ (beep).
3. Enter 9 9 9 9 then press * (beep).
4. Hang up the doorman telephone to end the programming session.
Function Section Default Description
54 3.1.2 0 1882 Relay boards
07 3.1.3 0011 Highest available relay
41 3.1.5 1234567890 Caller ID default number
08 3.1.6 60 Talk time in seconds
04 3.1.7 5,2 5 rings, double ring
05 3.1.8 98 76 Relay tone numbers
03 3.1.9 01 Relay strike time
13 3.2.2 1 Programmable directory codes OFF
09 3.3.1 F mmed FFF Outside line access code not progra
51 3.5.1 0 Do not disturb OFF
45 3.6.1 0 Call forwarding OFF
52 3.7.1 0 Virtual doorman OFF
53 3.7.2 01 strike time Virtual doorman relay
12 4.1.1 1 Lobby panel ON