Owner’s Manual Model 1808 and 1810 Access Plus Systems PC Programmable Telephone Entry / Access Control System DoorKing, Inc.120 Glasgow AvenueIn
1.2 Dimensions Surface Mount 1810 Access Plus DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.Surface Mount Case and Mounting Hole DimensionsRev.Ti
Surface Mount 1810 Access Plus with Recess Box/Trim Ring 2.687 6.01.125.437 2.0633.511.3753.5 2.187.25 DIA10.12513.3752.1873.37510-24 x 1.25 STUD (4 P
Flush Mount 1810 Access Plus 3.013.02.51.625.875 DIA1.1251.12512.0.875.502.625 2.6255.625.875 DIA11.2513.2510.875DOORKING, INC., INGLEWOOD, CA 90301
Flush Mount Rough-in Box (1810 Access Plus only) 1.91410.8863.4001.125 DIA (3 PL)3.4501.30014.6001.7401.7401.7004.700.275 DIA (3 PL)Flush Mount Rough-
Flush Mount Trim Ring (1810 Access Plus only) 1.5753.10012.2001.250 DIA (3 PL)3.45013.55514.7001.250 DIA (3 PL)10.88616.055DOORKING, INC., INGLEWOOD,
Surface Mount Trim Ring for Flush Mount Units (1810 Access Plus only) 2.62513.51.125 DIA 1.125 SQ.375.8751.1259.07.56.03.0.3751.012.0DOORKING, INC.,
Surface Mount 1808 Access Plus 6.3753.3757.3752.6253.0.875.8753.503.501808 Surface Mount HousingDOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.180
Postal Switch Installation (1810 Access Plus only) The 1808 Access Plus unit does not have provisions for the installation of the postal switch. If l
Page 18 1810-162-K-3-14
1.3 Power Wiring Do not run telephone lines / data lines and high voltage lines in the same conduit. Separate high voltage and telephone / data line c
Page 2 1810-162-K-3-14
1.4 Telephone Auto-Dialer Wiring – Single Unit DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No. Rev.Title:1/12CM1810-AP-6-CAccess Plus System Auto
1.5 Telephone Auto-Dialer Wiring – Multiple Units DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No. Rev.Title:1/12CM1810-AP-3-CAccess Plus System A
1.6 Telephone Intercom Wiring 1982 Relay Board1881 Decoder BoardBBRJ71CBlock 1RJ71CBlock 2CCRelay 01Relay 11ThruRelay 12Relay 23Thru1816 Access Plus
1.7 1816 Access Plus Detail Wiring 1881 Decoder Board12345678910DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No. Rev.Title:1/12CM1810-AP-4-CAcces
Page 24 1810-162-K-3-14
1.8 Main Terminal Description Terminal Description 1 Phone In (Negative) 2 Phone In (Positive) 3 Ground 4 Phone Out (Positive) 5 Phone Out (Neg
1.9 Access Plus Interface Board The Access Plus interface board is piggybacked onto the main Access Plus circuit board. The interface board provides
RS-485 Connections SW3SW2SW411121316 15 141712345678910OFFDOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No. Rev.Title:1/12DM1810AP-002-DAccess Plus
Page 28 1810-162-K-3-14 1.9.2 Network Connections There are a number of ways to communicate with the Access Plus unit via a network connection. B
Direct Connection Using a Crossover CableCrossover CableDirect Connection Using a Router (LAN)123456789101112131415161718MicVolMasterCode1 2 3 4 5 6 7
Use this manual with the following models only. 1808 and 1810 Access Plus Telephone Entry / Access Control Systems with circuit board 1970-010. Door
123456789101112131415161718MicVolPage 30 1810-162-K-3-14 MasterCode1234567891011SpeakerVolKeypadPhone / CableCompany InputModemN.I.D.1 2 3 4Router
1.9.3 Modem Connections Access Plus unit’s have a built-in modem that can be used to connect to a PC. Before programming can be attempted, you need t
SECTION 2 – PROGRAMMING Before You Start IMPORTANT! We strongly suggest that you become familiar with these programming instructions before beginnin
1810-162-K-3-14 Page 33 2.2 Programming Methods Access Plus units can be programmed from a computer, the unit’s keypad or from a touch-tone telepho
Page 34 1810-162-K-3-14 2.3 Programming with a Computer (Network Setup) Before proceeding with any of the programming steps in this section, inst
1810-162-K-3-14 Page 35 2.3.3 Sub-Net Mask (reboot required) Default value is: 255.255.255.000 All sub-net mask should be set to 255.255.255.000.
Page 36 1810-162-K-3-14 2.4 System Parameters Programming IMPORTANT! We strongly suggest that you read these programming instructions in their
System Parameters Programming Section 2.4 Description Command Section Default Value Single / Multiple Units * 6 1 2.4.1 Single Single or Double Ri
Page 38 1810-162-K-3-14 2.4.1 Single or Multiple Units Default setting is 1 (Single Unit). Set for single if only one Access Plus unit is connect
1810-162-K-3-14 Page 39 2.4.3 Number of Rings to Ring Residence Default setting is 05 (5 Rings). This programming step is only used if the Access
Page 4 1810-162-K-3-14 Table of Contents Preface Important Notices...
2.4.6 Tone Open Numbers Default setting is 9876 for relay 1; 5432 for relay 2. Relays 3 – 8 are not set. These steps will program the tone open numb
1810-162-K-3-14 Page 41 2.4.8 Hang Up Tone Default setting is 0. These steps set the number that will hang-up the Access Plus unit after conversat
Page 42 1810-162-K-3-14 2.4.11 Set Microphone Gain and Speaker Volume Default setting is 71. This adjustment is required only if the Access Plus
1810-162-K-3-14 Page 43 2.5 Directory Codes 2.5.1 Directory Codes 01 – 23 1816 Intercom Relay Programming Default Value is 0 (Directory codes 01-
Page 44 1810-162-K-3-14 2.6 Access Devices NOTE: All access codes are five (5) digits in length. 2.6.1 Simple Access Code Programming This prog
1810-162-K-3-14 Page 45 2.6.4 Device Access Code Programming This programming sequence programs device (card readers, keypads, RF receivers, etc.)
Page 46 1810-162-K-3-14 2.6.7 Temporary Device Access Code Programming This programming sequence programs up to 10 temporary device access codes
1810-162-K-3-14 Page 47 2.7 Time Functions 2.7.1 Program Calendar Chip This programming sequence programs the calendar chip in the Access Plus un
Page 48 1810-162-K-3-14 2.7.2 Relay Hold Schedule Default setting in step 3 is 0 (Hold schedules are OFF). This program sequence sets up schedule
1810-162-K-3-14 Page 49 2.7.3 Time Zones Default setting in step 3 is 0 (Time Zones are OFF). This programming sequence sets up time zones (up to 4
1810-162-K-3-14 Page 5 2.5 Directory Codes 2.5.1 Directory Codes 01 – 23 1816 Intercom Relay Programming...
Page 50 1810-162-K-3-14 2.8 Miscellaneous 2.8.1 Restore Defaults This step will restore the factory set defaults for each of the programming para
SECTION 3 – ADJUSTMENTS Speaker Volume The speaker volume potentiometer is labeled SPEAKER VOL on the control board. The speaker volume should be adj
Interface Board LED Status ONSW1 MODEM / TCP ENB12345678BAD DNSRS-485 RXLAN DOWNPhone Line In UseLAN ConnectionData TransmitSW2ONTERMINATIONOFF RS-4
1810-162-K-3-14 Page 53 SECTION 4 – USER INSTRUCTIONS 4.1 Resident Operating Instructions 4.1.1 Granting or Denying a Guest Access To place a ca
Page 54 1810-162-K-3-14 4.1.3 Dial-Connect (1816 intercom) To use the dial-connect feature, the guest simply presses a two-digit directory code (
1810-162-K-3-14 Page 55 4.2 Remote Operation 4.2.1 Remote Programming The Access Plus unit can be programmed and operated from a remote location u
Page 56 1810-162-K-3-14 4.2.3 Relay Activation Check The Access Plus unit can be called to check if relay 1, relay 2, or both relays on the uni
1810-162-K-3-14 Page 57 SECTION 5 – MAINTENANCE The DoorKing Access Plus system is essentially a maintenance free device. When the unit is proper
5.2 Troubleshooting Tables SYMPTOM POSSIBLE SOLUTION(S) Board does not power up. No power. Check for 16 VAC input power. If OV LED is ON, input
5.3 Wire Diagram 123456789101112131415161718MicVolMasterCode1234567891011SpeakerVolKeypad12345678ONMODEM / TCP ENBSW 1RedWhiteGreen+-GrayOrangePurpleW
Page 6 1810-162-K-3-14 Important Notices FCC – United States This equipment has been tested and found to comply with the limits for a class A digi
Page 60 1810-162-K-3-14 5.4 Accessories RS-485 Card Reader P/N 1815-232 (DKS Reader) RS-485 Card Reader P/N 1815-233 (AWID Reader) RS-485 Card
5.5 Tables Complete the information in the tables on the following pages to maintain a record of the information that has been programmed into the 181
Directory Codes / Dial-ConnectDirectory Code Name Apartment Number 02 03 04 05 06 07 08 09 10 11 12 13 14 15
Directory Codes / Auto-Dial NumbersDirectory Code Name Phone Number 24 25 26 27 28 29 30 31 32 33 34 35 36 37
Access Code Log Sheet Page 64 1810-162-K-3-14 Name Device Access Code Device Type Time Zone Schedule Number Relay Momentary or Hold
1810-162-K-3-14 Page 65 Name Device Access Code Device Type Time Zone Schedule Number Relay Momentary or Hold
1810-162-K-3-14 Page 7 General Information Prior to beginning the installation of the telephone entry system, we suggest that you become familia
Page 8 1810-162-K-3-14 Features IP Addressable – program from your PC using the DoorKing programming software via a LAN or WAN connection, or v
SECTION 1 - INSTALLATION Installation of the Access Plus Telephone Entry and Access Control System involves the installation of the hardware and the
Comments to this Manuals