Use this manual for circuit board 4404-010 Revision A or higher.
UL 325 Compliant
Installation/Owner’s Manual
Series 9200
Series 9200
Series 9200
Copyright 2009 DoorKing, Inc. All rights reserved.
TM
Copyright 2013 DoorKing, Inc. All rights reserved.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Heavy-Duty Vehicular Slide Gate Operator
Circuit Board
Serial Number
and Revision Letter:
WARNING
M
OVING
GATE CAN
CAUSE
O
pe
r
a
t
e
ga
t
e
onl
y
w
h
en ga
t
e
a
re
a
i
s
i
n
s
ig
h
t
a
nd
f
re
e
of
p
e
opl
e
and
o
bs
t
r
u
ct
i
on
s.
D
o
n
ot
a
llow
c
h
i
ld
r
e
n
t
o
p
l
a
y in ga
t
e
a
r
e
a
or ope
r
a
te
ga
t
e
.
Do
n
ot
s
t
a
nd
i
n
g
a
t
e
pa
th
o
r
wa
l
k
thr
o
ugh
pa
t
h wh
i
le
ga
t
e
i
s
m
o
ving.
Re
a
d
ow
ne
r
’s
m
a
n
ua
l
a
nd
s
af
et
y
i
ns
t
ruct
i
o
ns
.
SERIOUS INJU
RY OR DE
AT
H
C
LA
S
S
C
ERT
IF
I
ED TO
CA
N/
C
S
A
C2
2.2 NO.
2
47
CONF
ORM
S
TO
AN
S
I/U
L-3
25
VE
H
I
CU
LA
R
GATE
O
P
ER
ATO
R
HP
53382
M
ODE
L
S
ERIA
L
V
OL
TS
P
HA
S
E
A
M
P
S
6
0
Hz
M
AX
GA
TE LO
A
D
Do
orKing
,
I
n
c
.,
I
ng
le
wo
od
, CA
9210-065-H-2-13
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - Series 9200

Use this manual for circuit board 4404-010 Revision A or higher.UL 325 CompliantInstallation/Owner’s ManualSeries 9200Series 9200Series 9200Copyright

Page 2

9210-065-H-2-138Note: A filler post or barrier may need to be installed in the gap area to reduce the distance to 2 1/4 inches or less. A contact sens

Page 3 - SPECIFICATIONS

9210-065-H-2-139Slide Gate Protection ReverseLoopAutomatic Exit Loop Minimizes the potential of the gate closing when a vehicle is present. Number and

Page 4 - TABLE OF CONTENTS

9210-065-H-2-13101.2 Underground Conduit Requirements Primary/Secondary Interconnection Cable (Dual Operator Application Only) Sweeps Concrete Pad Con

Page 5

9210-065-H-2-13111.3 Installation Options #1 - Operator Mounted Directly on a Concrete Pad#2 - Operator Mounted on the Heavy-Duty Pedestal Mounting St

Page 6

9210-065-H-2-13121.3 ContinuedPedestal mounting stand and chain tray recommended for gates over 20 ft.Pedestal mounting stand and chain tray recommend

Page 7 - Important Notices

9210-065-H-2-13131.4 Installation #1Remove the limit assembly guard. Remove the 3 locknuts inside the electronic box to swing box open.WARNINGMOVING G

Page 8 - Class III Class IV

9210-065-H-2-13141.5 Installation #2Pad depth is determined by soil conditions and local building codes. Minimum depth is 18 inches. Reinforced concre

Page 9 - Glossary

9210-065-H-2-13151.5 Continued - Chain Tray KitTip: Chain tray supporting brackets can be mounted facing down (as shown on right), facing up or extend

Page 10 - High Risk of Entrapment Area

9210-065-H-2-13161.6 Chain InstallationDirectly on a Concrete Pad - #1 Factory Set Idler WheelsHeavy-Duty Pedestal Mounting Stand - #2 Lower Idler Whe

Page 11 - 9210-065-H-2-13

9210-065-H-2-13171.7 Installation of Warning SignsThis DoorKing Slide Gate Operator is shipped with two warning signs. The purpose of the warning sign

Page 13 - 1.3 Installation Options

9210-065-H-2-13181232.2 High Voltage Terminal Connection• Route incoming AC power wire through the high voltage conduit and run wire in the operator

Page 14 - Heavy-Duty Box Frame Roller

9210-065-H-2-13194404-010TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P620 19 18 17 16 15 14 13 12 11

Page 15 - Operator Mounted Directly

9210-065-H-2-13201ON2 3 4 5 6 7 8 1ON2 3 43.2 DIP-Switch SW 1 and SW 2 Settings The two DIP-switches located on the circuit board are used to program

Page 16 - 1.5 Installation #2

9210-065-H-2-13213.2 ContinuedSwitch 1 This switch is a self-test feature that checks various functions of the circuit board and is used for bench tes

Page 17 - Installing the Chain Tray Kit

9210-065-H-2-13224404-010TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P620 19 18 17 16 15 14 13 12 11

Page 18 - 1.6 Chain Installation

9210-065-H-2-13233.4 Inherent Reverse Sensors Adjustment Test the operator reversing sensitivity:Momentarily jumper a wire across terminals 1 and 4 to

Page 19 - 2.1 High Voltage Wire Runs

9210-065-H-2-13241256111221413A13B13C152523031TXATXBUL1 L2 L3VT2WB-B+ModeEPMT1 T32. 0 SCF seriesbasic I/O controlThere are 2 speed adjustments that mu

Page 20 - 208/230 VAC

9210-065-H-2-13254404-010Note: The 6-pin terminal can be unplugged from circuit board for easy wire connections.All inputs are normally open (NO).6-Pi

Page 21 - SECTION 3 - ADJUSTMENTS

9210-065-H-2-1326TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-10120 19 18 17 16 15 14 13 12 11

Page 22 - Left 4 Switches - SW 2

9210-065-H-2-1327TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-10120 19 18 17 16 15 14 13 12 11

Page 23 - 3.2 Continued

9210-065-H-2-131Class of Operation Series 9200 - UL 325 Class III, IV Type of Gate Vehicular Slide Gates OnlyMax Gate Length 100 Ft (Installed Leve

Page 24 - Adjust Limit Nuts

9210-065-H-2-13284404-010TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P620 19 18 17 16 15 14 13 12 11

Page 25 - Voltage and Phase Turns

9210-065-H-2-1329NCNOP720 1919181817 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1Current SensorCurrent SensorEarth GroundMotor HotMotor NeutralDry Relay Con

Page 26 - SCM series

9210-065-H-2-1330NCNOP720 19 18 17 16 15 14 13 12 11 10 9 87654321EMERGENCYCLOSERed Full OpenGreen CloseWhite ComKey SwitchStand-AloneKeypadStand-Alon

Page 27 - Electronic Box

9210-065-H-2-13314404-010NC NO P7 20 19 18 17 16 15 14 13 12 11 10 9 876 5 4 3 2 1Gate Tracker (Quad Box Shown) Remote Alarm Reset Station(DoorKing

Page 28 - 2 3 4 5 6 7 8

9210-065-H-2-13324404-0104404-010NC NO P7 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 UL 325 Terminal UL 325 Terminal UL 32

Page 29 - (If necessary)

9210-065-H-2-1333WARNING MOVING GATE CAN CAUSE Operate gate only when gate area is in sight and free of people and obstructions. Do not allow childre

Page 30 - Automatic Exit Loop

9210-065-H-2-13346.2 Shutdown ConditionsUnder various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determ

Page 31 - 5.1 Main Terminal Description

9210-065-H-2-1335WARNING MOVING GATE CAN CAUSE Operate gate only when gate area is in sight and free of people and obstructions. Do not allow childre

Page 32 - 9235 Model Operator

9210-065-H-2-13367.1 MaintenanceSECTION 7 - MAINTENANCE AND TROUBLESHOOTINGInspection and service of this gate operator by a qualified technician shou

Page 33 - 5.3 Auxiliary Device Wiring

9210-065-H-2-13377.3 Troubleshooting7.2 Built-In Diagnostic TestsHave a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of ch

Page 34 - Interconnection Cable

9210-065-H-2-132SPECIFICATIONS 1SECTION 1 - INSTALLATION 10SECTION 2 - AC POWER TO OPERATOR(S) 17Gate ConstructionImportant Safety InstructionsInstruc

Page 35

9210-065-H-2-1338• Check the input LEDs. Any ON will hold the gate open and indicates a problem with a keying device. • Check the secondary safety d

Page 36 - Resetting a Hard Shutdown

9210-065-H-2-13397.4 Accessory ItemsThe following accessory items are available for the series 9200 slide gate operators.Contact Sensors - For use as

Page 37 - 6.3 Manual Gate Operation

Use this manual for circuit board 4404-010 Revision A or higher.Copyright 2009 DoorKing, Inc. All rights reserved.www.doorking.comDoorKing, Inc.120 Gl

Page 38 - Monthly Interval

9210-065-H-2-133293031325.1 Main Terminal Description5.2 Control Wiring for Single/Primary Operator5.3 Auxiliary Device Wiring5.4 Bi-Parting Gates

Page 39 - 7.2 Built-In Diagnostic Tests

9210-065-H-2-134ASTM F2200 Standard for Gate ConstructionInstructions regarding intended installation: Vehicular gates should be constructed and insta

Page 40 - Symptom Possible Solution

9210-065-H-2-135• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or ob

Page 41 - 7.4 Accessory Items

9210-065-H-2-136UL325 Entrapment Protection Class I Class I and II Class III Class IV Class II Class III Class IV A vehicular gate operator (or syste

Page 42

9210-065-H-2-137GlossaryGATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage ba