Installation/Owner’s Manual
Series 9500
Series 9500
Series 9500
Copyright 2009 DoorKing, Inc. All rights reserved.
TM
Copyright 2013 DoorKing, Inc. All rights reserved.
Use this manual for circuit board 4404-010 Revision A or higher.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Maximum Security Heavy-Duty Vehicular Slide Gate Operator
UL 325 Compliant
Circuit Board
Serial Number
and Revision Letter:
W
A
RNI
N
G
M
OV
I
NG
G
ATE
C
AN
C
A
US
E
O
per
at
e
g
a
t
e
o
n
l
y
wh
e
n
g
at
e
a
r
e
a
i
s
in
s
i
g
ht
a
n
d
f
r
e
e
o
f
p
e
op
l
e
a
n
d
o
b
s
t
r
u
ct
i
o
n
s
.
D
o
no
t
a
l
lo
w
c
h
i
l
d
r
e
n
t
o
p
l
ay
i
n
g
a
t
e
a
r
e
a
o
r
o
p
e
r
a
t
e
g
a
t
e
.
D
o
n
o
t
s
t
a
nd
i
n
g
a
te
p
a
t
h
o
r
w
a
l
k
t
h
r
o
u
gh
p
a
t
h
w
h
ile
ga
t
e
i
s
m
o
v
i
n
g
.
R
ea
d
o
wne
r
s
m
a
n
u
a
l
a
n
d
s
af
e
t
y
i
ns
t
r
u
c
t
io
n
s
.
S
E
R
IO
U
S
IN
J
U
R
Y
O
R
D
EA
T
H
9510-065-L-3-13
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Series 9500

Installation/Owner’s ManualSeries 9500Series 9500Series 9500Copyright 2009 DoorKing, Inc. All rights reserved.TMCopyright 2013 DoorKing, Inc. All righ

Page 2

9510-065-L-3-138UL325 Entrapment Protection Class I Class I and II Class III Class IV Class II Class III Class IV A vehicular gate operator (or syste

Page 3 - SPECIFICATIONS

9510-065-L-3-139Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage b

Page 4 - SECTION 3 - ADJUSTMENTS 17

9510-065-L-3-13101.3 Underground Conduit Requirements Primary/Secondary Interconnection Cable (Dual Operator Application Only) Padlock Bracket Chassis

Page 5 - TABLE OF CONTENTS

9510-065-L-3-131156” 36” 4” 10.5”24” depth up to 8,000 lb. gate.36” depth up to 25,000 lb. gate.4” 10.5”12”12”12” 12” 12” 12” Wire Mesh 1.4 Concrete P

Page 6 - Slide Gate Requirements

9510-065-L-3-1312Gate TypesWARNINGMOVING GATE CAN CAUSEHeavy-Duty Box Frame CantileverHeavy-Duty Box Frame RollerHeavy-Duty Ornamental CantileverWARNI

Page 7 - Illustration not to scale

9510-065-L-3-13131.5 Mounting Operator and Chain Operator MUST be parallel to gate! DoorKing recommends twelve (12) 1/2” x 3” sleeve anchors (not supp

Page 8

9510-065-L-3-13141.7 Installation of Warning Signs 1.6 Installation of Chain Tray This DoorKing Slide Gate Operator is shipped with two warning signs.

Page 9 - Important Notices

9510-065-L-3-13152.1 High Voltage Wire RunsThe 9500 draws significant power and each operator should have a “Dedicated” circuit breaker at the power s

Page 10 - Classifications

9510-065-L-3-1316PUSH TO OPERATEtechnician use onlyOFFONOPENCLOSESTOP2.2 High Voltage Terminal ConnectionRemove the 3 locknuts inside the electronic b

Page 11 - Glossary

9510-065-L-3-1317TIME DELAY EXIT LOOP LMT LMT REVERSELOOPREV SENSE OPEN REV SENSE CLOSE 1 ON 2 3 4 1 ON 2 3 4 5 6 7 8 NC NO P8 P7 P6 4404-0102

Page 13 - Front View

9510-065-L-3-13183.2 DIP-Switch SW 1 and SW 2 SettingsThe two DIP-switches located on the circuit board are used to program the operator to operate i

Page 14 - Ornamental

9510-065-L-3-13193.2 ContinuedThe two DIP-switches located on the circuit board (Upside-Down )are used to program the operator to operate in various m

Page 15 - 9510-065-L-3-13

9510-065-L-3-1320TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-01020 19 18 17 16 15 14 13 12 11

Page 16 - Chain Tray Segment Connection

9510-065-L-3-1321OPENCLOSE3.4 Inherent Reverse Sensors AdjustmentTest the operator reversing sensitivity:Press the OPEN button on the 3-push button to

Page 17 - 2.1 High Voltage Wire Runs

9510-065-L-3-13223.6 AC Module Adjustment9500s are equipped with an AC module that allows you to adjust the speed of the gate from 0 to 2 ft/ sec or 0

Page 18 - 208/230/

9510-065-L-3-1323Note: The 6-pin terminal can be unplugged from circuit board for easy wire connections.All inputs are normally open (NO).6-Pin UL 325

Page 19 - SECTION 3 - ADJUSTMENTS

9510-065-L-3-1324TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-10120 19 18 17 16 15 14 13 12 11

Page 20 - Left 4 Switches - SW 2

9510-065-L-3-1325TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-10120 19 18 17 16 15 14 13 12 11

Page 21

9510-065-L-3-1326TIMEDELAYEXITLOOPLMTLMTREVERSELOOPREV SENSEOPENREV SENSECLOSE1ON2 3 41ON2 3 4 5 6 7 8NCNOP8P7P64404-01020 19 18 17 16 15 14 13 12 11

Page 22 - 3.3 Limit Switches

9510-065-L-3-1327This input ONLY fuctions when gate is fully opened or in the closing cycle.• When gate is closing: SW 1, switch 7 is OFF, an input to

Page 23 - Voltage and Phase Turns

9510-065-L-3-13159”39”20”26”15”SPECIFICATIONSWARNINGMOVING GATE CAN CAUSEOperate gate only when gate area is in sightand free of people and obstructio

Page 24 - 15 HP AC Module

9510-065-L-3-1328NCNOP720 19 18 17 16 15 14 13 12 11 10 9 87654321Important: Controls intended for user activation must be located at least six (6) fe

Page 25 - Electronic Box

9510-065-L-3-1329NC NO P7 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1Gate Tracker (Quad Box Shown) Remote Alarm Reset Station(DoorKing P/N 1

Page 26 - 2 3 4 5 6 7 8

9510-065-L-3-1330NCNOP720 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 43211234 5 6UL 325TerminalUL 325TerminalUL 325TerminalUL 325TerminalPrimary Operator

Page 27 - (If necessary)

9510-065-L-3-1331SECTION 6 - OPERATING INSTRUCTIONSWARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. N

Page 28 - 4.3 Loop Detector Wiring

9510-065-L-3-13326.2 Shutdown ConditionsUnder various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determ

Page 29 - 5.1 Main Terminal Description

9510-065-L-3-13336.3 Manual Gate OperationCaution: Never attempt to manually operate any gate until you have verified that power to the operator has b

Page 30 - SW 1 is Upside-Down on Board

9510-065-L-3-13347.1 MaintenanceSECTION 7 - MAINTENANCE AND TROUBLESHOOTINGInspection and service of this gate operator by a qualified technician shou

Page 31 - 5.3 Auxiliary Device Wiring

9510-065-L-3-13357.3 Troubleshooting7.2 Built-In Diagnostic TestsHave a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of ch

Page 32 - Interconnection Cable

9510-065-L-3-1336• Check the input LEDs. Any ON will hold the gate open and indicates a problem with a keying device. • Check the secondary safety d

Page 33

9510-065-L-3-13377.4 Accessory ItemsThe following accessory items are available for the series 9500 slide gate operators.Contact Sensors - For use as

Page 34 - 6.2 Shutdown Conditions

9510-065-L-3-132SPECIFICATIONS 1SECTION 1 - INSTALLATION 10SECTION 2 - AC POWER TO OPERATOR(S) 15SECTION 3 - ADJUSTMENTS 17Slide Gate RequirementsSafe

Page 35 - Remove the Cover

Copyright 2009 DoorKing, Inc. All rights reserved.www.doorking.comDoorKing, Inc.120 Glasgow AvenueInglewood, California 90301U.S.A.Phone: 310-645-0023

Page 36 - Monthly Interval

9510-065-L-3-133SECTION 7 - MAINTENANCE AND TROUBLESHOOTING 347.1 Maintenance7.2 Built-In Diagnostic Tests7.3 Troubleshooting7.4 Accessory Items34353

Page 37 - 7.2 Built-In Diagnostic Tests

9510-065-L-3-134Slide Gate RequirementsThe operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a

Page 38 - Symptom Possible Solution

9510-065-L-3-135ReverseLoopAutomaticExit LoopMinimizes the potential of the gate closing when a vehicle is present. Number and placement of loops is d

Page 39 - 7.4 Accessory Items

9510-065-L-3-136Instructions regarding intended installation: Vehicular gates should be constructed and installed in accordance with ASTM F2200; Stand

Page 40

9510-065-L-3-137• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or ob

Comments to this Manuals

No comments