Doorking 1812 Classic User Manual

Browse online or download User Manual for Communication Doorking 1812 Classic. DoorKing 1812 Classic User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
UL Listed
Copyright 2009 DoorKing, Inc. All rights reserved.
Copyright 2013 DoorKing, Inc. All rights reserved.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Circuit Board
Serial Number
and Revision Letter:
7
8 9
4 5 6
1 2 3
0
7
8 9
4 5 6
1 2 3
0
7
8 9
4 5 6
1 2 3
0
Wall Mount
Flush Mount
Surface Mount
Installation/Owner’s Manual
Model 1812 Classic
Model 1812 Classic
Model 1812 Classic
Use this manual for circuit board 1871-010 Revision S or higher.
Control a main door and gate.
Residential Telephone Intercom/Access Control System
Push Button
Push Button
To Call
To
Call
Push Bu
t
ton
Push
B
utton
To Call
To
Call
1812-065-U-12-13
Page view 0
1 2 3 4 5 6 ... 45 46

Summary of Contents

Page 1 - Installation/Owner’s Manual

UL ListedCopyright 2009 DoorKing, Inc. All rights reserved.Copyright 2013 DoorKing, Inc. All rights reserved.Date Installed:Installer/Company Name:Pho

Page 2

1812-065-U-12-138SECTION 1 - INSTALLATIONInstallation of the 1812 Classic Telephone Entry System involves the installation of the hardware, by-pass bo

Page 3 - SPECIFICATIONS

1812-065-U-12-139Different Mounting Configurations of the 1812 Classic ModelsSurface and Wall mount models can be mounted directly to a wall, pilaster

Page 4

1812-065-U-12-1310Mount rough-in box into the pilaster, wall or kiosk. Run conduit inside wall into bottom of rough-in box if desired. Use appropriate

Page 5

1812-065-U-12-13111CENTRALOFFICEEARTHGNDPHONEINPHONEOUTHOME2345678SW1ENTRY BY-PASS1875-0101CENTRALOFFICEEARTHGNDPHONEINPHONEOUTHOME2345678SW1ENTRY BY-

Page 6 - TABLE OF CONTENTS

1812-065-U-12-1312TelephoneWire ConduitHigh VoltagePower WireConduitElectrical field from power wires.18” minimumUnderground CutawayNote: Do not run t

Page 7

1812-065-U-12-1313Proper Grounding and the use of surge suppressors can significantly reduce the chance of component failure because of static charges

Page 8 - Important Notices

1812-065-U-12-13141CENTRALOFFICEEARTHGNDPHONEINPHONEOUTHOME2345678SW1ENTRY BY-PASS1875-0101.6 Wire One 1812 to a Telco Line - Telephone ModeUse minimu

Page 9 - General Information

1812-065-U-12-1315MASTERCODEON1CENTRALOFFICEEARTHGNDPHONEINPHONEOUTHOME2345678SW1ENTRY BY-PASS1875-0101.7 Wire One 1812 to the Internet - Telephone Mo

Page 10 - 1.1 Mount the 1812 Classic

1812-065-U-12-1316MASTERCODEONMASTERCODEONEARTHGND1CENTRALOFFICEPHONEINPHONEOUTHOME2345678SW1ENTRY BY-PASS1875-0101CENTRALOFFICEEARTHGNDPHONEINPHONEOU

Page 11 - Mount on a Mounting Post

1812-065-U-12-1317MASTERCODEONHomeowner’s PhoneLAN/Cordless1.9 Wire One 1812 - Intercom ModeLOW VOLTAGE LINEOUTOUT1878-010ININGNDGNDINPUTOUTPUTPhoneJa

Page 13 - ENTRY BY-PASS

1812-065-U-12-1318MASTERCODEONMASTERCODEON16.5VACMainTerminal1871-010Phone In(1-2)Phone Out(4-5)MASTMASTCODRelay 1Relay 2Power16.5VACMainTerminal1871-

Page 14 - 1.3 Telephone Line Wire

1812-065-U-12-1319181716151413121110987654321MASTERCODEON1871-0101.11 Main Terminal DescriptionPhone Out(Twisted Pair)Time ClockRelay 1(Access Control

Page 15 - 1.4 Power Wiring

1812-065-U-12-1320181716151413121110987654321MICVOLFB1FB2SPEAKERVOLMASTERCODEON1871-010The master code is the four-digit number REQUIRED to gain acces

Page 16 - Access Control Devices

1812-065-U-12-1321 IMPORTANT! We strongly suggest that you read these programming instructions in their entirety before beginning any manual programm

Page 17 - Internet

1812-065-U-12-1322Phone Mode or Intercom ModeSystem Set-Up Code (4 #s): 1st #: Single or Multiple Systems 2nd #: System Attention Number 3rd #: Num

Page 18 - 1st 1812

1812-065-U-12-13232.3.2 System Set-up CodeFactory setting is 1 7 3 1.These steps will program the system’s “Basic” set-up. The system set-up code is a

Page 19

1812-065-U-12-13242.3.4 Relay Strike TimeFactory setting for Relays 1 and 2 is 01 (1 Second).System relays 1 and 2 are the two relays on the 1812 main

Page 20 - 2nd 1812

1812-065-U-12-13252.3.7 Answer Incoming Call - Enable / DisableFactory setting is 0 (Disable).The 1812 can be programmed to answer calls placed to the

Page 21 - SECTION 2 - PROGRAMMING

1812-065-U-12-13262.4 Time Functions2.4.1 Time and Date Calendar Chip ProgrammingThis programming sequence programs the calendar chip in the 1812 syst

Page 22 - 2.2 Master Code

1812-065-U-12-13272.4.3 Automatic Relay Activation Time Zones ProgrammingThis program sequence sets up time zones to automatically activate and deacti

Page 23 - Off-Site Touch-Tone Telephone

1812-065-U-12-131SPECIFICATIONSFeaturesSurface MountWall MountFlushMountDoorKing, Inc. reserves the right to make changes in the products described in

Page 24 - Quick Reference Table

1812-065-U-12-13282.4.5 Call Forward Time Zone ProgrammingThis programming sequence sets up a time zone for the call-forward feature. The 1812 must al

Page 25 - 2.3.3 Talk Time

1812-065-U-12-13292.5.2 Call Forward - Enable / DisableThis programming sequence Enables/Disables the call forward feature. You must have a call forwa

Page 26 - 2.3.5 Tone Open Numbers

1812-065-U-12-13302.6 Access Codes to Operate Access Control Devices2.6.1 Access Code ProgrammingThis programming sequence programs four-digit “Access

Page 27 - 1812-065-U-12-13

1812-065-U-12-1331181716151413121110987654321FB1FB2MASTERCODEON1871-010SPEAKERVOLMICVOL7788994455661 2 30011112222333333Push ButtonPush ButtonTo CallT

Page 28 - 2.4 Time Functions

1812-065-U-12-13324.1 Calling the Homeowner’s Phone from the 1812To place a call from the 1812 to the homeowner's house, the guest simply presses

Page 29

1812-065-U-12-13334.4 Access CodesThe access codes will operate either relay 1 or relay 2 with a specific function depending on the “location code”num

Page 30

1812-065-U-12-13344.6 Call Forward Time Zone - Enable / DisableTo use the call forward time zone feature, be sure that a call forward time zone has be

Page 31

1812-065-U-12-1335The 1812 can be programmed and operated from a remote location (Home or off-site) using a touch-tone telephone. Be sure that the pro

Page 32 - 2.6.3 Delete All Access Codes

1812-065-U-12-1336181716151413121110987654321MICVOLFB1FB2SPEAKERVOLMASTERCODEON1871-010SECTION 5 - MAINTENANCEThe DoorKing 1812 telephone entry system

Page 33 - SECTION 3 - ADJUSTMENTS

1812-065-U-12-1337MASTERCODEONEARTHGNDSW1ENTRY BY-PASS1875-0101CENTRALOFFICEPHONEINPHONEOUTHOME2345678TIPTIPTIPRINGRINGRINGTIPRINGEARTHGNDSW1ENTRY BY-

Page 34 - 4.2 Call Waiting

1812-065-U-12-13277889944556611223300SPECIFICATIONSSurface Mount Dimensions7788994455661 2 3001111222233333310” 5.25”6.125”2.5”2.5”1.125” Dia2.875”1.1

Page 35 - 4.4 Access Codes

1812-065-U-12-1338If noise or hum is present on the homeowner's phone line after installation of the 1812 telephone intercom system, use the proc

Page 36

1812-065-U-12-1339• Answer incoming call feature is disabled. Enable answer incoming call feature (2.3.7).• Number of rings to answer may be program

Page 37 - 4.13 Remote Relay Activation

1812-065-U-12-1340Secondary Keypads: Allows remote activation of the system relays by use of the access codes. Does not provide any voice communicatio

Page 38 - Push to Call Button

1812-065-U-12-1341Complete the information in the tables on the following pages to maintain a record of the information that has been programmed into

Page 39 - Fiber / VolP

1812-065-U-12-1342Function Access Code #Location CodeAccess Codes: 01 - 25 – Relay 1 26 - 50 – Relay 2Relay 1 Relay 201020304050607080910

Page 41 - Symptom Possible Solution(s)

www.doorking.comResidential Telephone Intercom/Access Control SystemInstallation/Owner’s ManualUse this manual for circuit board 1871-010 Revision S o

Page 42 - 5.6 Accessories

1812-065-U-12-133Rough-InBoxSPECIFICATIONSFlush Mount Dimensions7788994455661 2 300111122223333337.5”6.25”7.25”9.25”5”3.5”3.5”10.25”10”12”4.5”4.25”2.6

Page 43

1812-065-U-12-134SPECIFICATIONSFeaturesSurface Mount DimensionsWall Mount DimensionsFlush Mount DimensionsImportant Notices FCC - United States, DOC

Page 44 - Relay 1 Relay 2

1812-065-U-12-135TABLE OF CONTENTS2.5 Programming Dial-Out Functions 2.5.1 Call Forward Phone Number Programming 2.5.2 Call Forward - Enable / Di

Page 45

1812-065-U-12-136FCC – United StatesThis equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part

Page 46

1812-065-U-12-1371. If the clear floor space allows only forward approach to the system, the maximum high forward reach allowed is 48 inches above g