Summary of Contents

Page 1 - Owner’s Manual

Model 9310 Vehicular Slide Gate OperatorOwner’s Manual DoorKing, Inc.120 Glasgow AvenueInglewood, California 90301 U.S.A. Phone: 310-645-0023Fax:

Page 2 - Page 2 9310-065-H-8-08

Instructions regarding intended installation: Install the gate operator only if: 1. The operator is appropriate for the construction of the gate and

Page 3 - 9310-065-H-8-08 Page 3

For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such

Page 4 - QUICK START

Slide Gate Requirements GateRoadwayPedestrianAccessFenceVehicular GateSidewalkOperatorFenceAll openings of a horizontal slide gate are guarded or scr

Page 5 - 2 TIMER

Slide Gate Protection FenceOperatorPedestrianAccessFenceSidewalkReverseLoopReverse (Open)LoopOpen Loop(Optional)1112 34Loops to help minimize the pote

Page 6 - Glossary

Table of Contents Section 1 – Installation 1.1 Specifications ...

Page 7 - Entrapment Protection

Section 5 – Maintenance and Troubleshooting 5.1 Maintenance Schedule...

Page 8 - Important Notices

Page 16 9310-065-H-8-08

Page 9 - Gate Construction

SECTION 1 - INSTALLATION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the instructions, i

Page 10 - Page 10 9310-065-H-8-08

1.2 Concrete Pad The model 9310 vehicular gate operator is designed to be mounted on a concrete pad. 1. Construct a form for the mounting pad acco

Page 11 - 9310-065-H-8-08 Page 11

1.3 Operator Installation Position the operator on the pad so that there is a minimum clearance of one (1) inch between the back of the operator hous

Page 13 - 9310-065-H-8-08 Page 13

1.4 Chain Installation 1. Secure the chain brackets to each end of the gate so that the brackets are level with the top chain cutouts in the operato

Page 14 - Section 3 – Adjustments

1.5 Front Mount Installation 48GROUND LEVELCONCRETE PADREMOVEBREATHERPLUG PIN9310-065-H-8-08 Page 21

Page 15

1.6 Rear Mount 48GROUND LEVELCONCRETE PADREMOVEBREATHERPLUG PIN Gate BracketsIdler AssemblyP/N 2600-818Page 22 9310-065-H-8-08

Page 16 - Page 16 9310-065-H-8-08

1.7 Warning Sign Installation This DoorKing slide gate operator is shipped with two warning signs. The purpose of the warning signs is to alert uninfo

Page 17 - SECTION 1 - INSTALLATION

Page 24 9310-065-H-8-08

Page 18 - Page 18 9310-065-H-8-08

SECTION 2 – WIRING Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF po

Page 19 - 9310-065-H-8-08 Page 19

2.1 High Voltage Connections Use Table 1 to determine high voltage wire size requirements. The distance shown in the chart is measured in feet from th

Page 20 - Page 20 9310-065-H-8-08

2.2 Control Wiring Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the c

Page 21 - 9310-065-H-8-08 Page 21

2.3 Loop Detectors Loops and loop detectors must be installed with this gate operator to prevent the gate from accidentally closing on vehicles that m

Page 22 - Page 22 9310-065-H-8-08

2.4 Auxiliary Device Wiring 12345678910111213141516 17 184403-010Circuit BoardSecondary EntrapmentProtection InputsDOORKING, INC., INGLEWOOD, CA

Page 23 - 9310-065-H-8-08 Page 23

Use this manual with the following models only. All 9310 models with circuit board 4403-010. IMPORTANT! The 4403 circuit board used in the model 93

Page 24 - Page 24 9310-065-H-8-08

2.5 Primary – Secondary (Bi-parting) Gate Wiring The interface wiring between the two operators requires six (6) wires (18 AWG minimum) for control a

Page 25 - SECTION 2 – WIRING

2.6 Terminal Identification and Description 2.6.1 Main Terminal (P1) 1. 24 VOLT COMMON Same as terminal 13. 2. OPEN / RADIO RELAY Functions same

Page 26 - Page 26 9310-065-H-8-08

2.6.2 Secondary Device Terminal (P3) External entrapment prevention devices are connected here. 1. OPEN PHOTO-BEAM This input is only active when th

Page 27 - 9310-065-H-8-08 Page 27

SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is c

Page 28 - Page 28 9310-065-H-8-08

3.2 Switch Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or o

Page 29 - 9310-065-H-8-08 Page 29

3.2.1 Programming Switch Description and Function 8-DIP (Top) Switch Switch 1: Set so that the operator cycles open upon initial power up and open co

Page 30 - Page 30 9310-065-H-8-08

3.3 Limit Switch Adjustments 1. Be sure that power to the operator is OFF. 2. Push the gate to the open position. Adjust the OPEN limit nut so tha

Page 31 - 9310-065-H-8-08 Page 31

3.4 Reverse Sensitivity Adjustment This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sens

Page 32 - Page 32 9310-065-H-8-08

Page 38 9310-065-H-8-08

Page 33 - SECTION 3 - ADJUSTMENTS

SECTION 4 – OPERATING INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children ope

Page 34

Mount operator to pad using 3/8 or 1/2 sleeve anchors.See page 18-19.12Attach chain. Adjust chain to allow approximately 1-inch of sag per 10-feet of

Page 35 - 9310-065-H-8-08 Page 35

4.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard shutdown (alarm) condition. To determine w

Page 36 - Page 36 9310-065-H-8-08

4.2.3 Hard Shutdown A hard shutdown condition occurs when the inherent entrapment protection system has sensed two consecutive obstructions before the

Page 37 - 9310-065-H-8-08 Page 37

4.3 Manual Gate Operation This operator is equipped with a manual release system that will allow the gate to be pushed open in the event of a power ou

Page 38 - Page 38 9310-065-H-8-08

4.3.3 Fail-Secure Manual Operation The FAIL-SECURE option locks the gate when primary (AC) power is removed and requires a keyed release to place the

Page 39 - 9310-065-H-8-08 Page 39

Page 44 9310-065-H-8-08

Page 40 - Page 40 9310-065-H-8-08

SECTION 5 – MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malf

Page 41 - 9310-065-H-8-08 Page 41

5.2 Operator Diagnostics This gate operator is designed with built-in diagnostics that will alert you to potential or existing problems that the micro

Page 42 - Page 42 9310-065-H-8-08

5.3 Trouble Shooting Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is

Page 43 - 9310-065-H-8-08 Page 43

Gate opens a short distance, then stops and reverses. • Disconnect the gate from the gate operator and check that the gate slides freely without an

Page 44 - Page 44 9310-065-H-8-08

5.4 Accessories The following accessory items can be used with the model 9310 slide gate operator. Contact Sensor Contact sensors for use as a sec

Page 45

94109410EXIT LOOPREVERSE LOOPON1231 DIRECTION2 TIMER1 Open Cycle Photocell2 Close Cycle Photocell3 Open Cycle Contact Sensor4 Close Cycle Contac

Page 46 - Page 46 9310-065-H-8-08

Title:Date: Rev.Dwg. No.DOORKING, INC., INGLEWOOD, CA 903011 2 3 4 5N.O.N.C.COMN.O.N.C.COMWhiteRedYellowBlueLimit LimitPartial LimitP2 P112345678910

Page 47 - SYMPTON POSSIBLE SOLUTION(S)

Title:Date: Rev.Dwg. No.DOORKING, INC., INGLEWOOD, CA 903011 2 3 4 5N.O.N.C.COMN.O.N.C.COMWhiteRedYellowBlueLimit LimitPartial LimitP2 P112345678910

Page 48

Title:Date: Rev.Dwg. No.DOORKING, INC., INGLEWOOD, CA 903011 2 3 4 5N.O.N.C.COMN.O.N.C.COMWhiteRedYellowBlueLimit LimitPartial LimitP2 P112345678910

Page 49 - 9310-065-H-8-08 Page 49

Title:Date: Rev.Dwg. No.DOORKING, INC., INGLEWOOD, CA 903011 2 3 4 5N.O.N.C.COMN.O.N.C.COMWhiteRedYellowBlueLimit LimitPartial LimitP2 P112345678910

Page 50 - Page 50 9310-065-H-8-08

Title:Date: Rev.Dwg. No.DOORKING, INC., INGLEWOOD, CA 903011 2 3 4 5N.O.N.C.COMN.O.N.C.COMWhiteRedYellowBlueLimit LimitPartial LimitP2 P112345678910

Page 51 - For 3 Phase power input

9310-065-H-8-08 Page 55

Page 52 - Page 52 9310-065-H-8-08

Glossary GATE: A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is tha

Page 53 - 9310-065-H-8-08 Page 53

Entrapment Protection Protection Against Entrapment Gate Operator Category Horizontal Slide, Vertical Lift, Vertical Pivot Swing and Vertical Barrier

Page 54 - Page 54 9310-065-H-8-08

Important Notices Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gat

Page 55 - 9310-065-H-8-08 Page 55

Important Safety Instructions WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate o