DoorKing 6003 Owner's Manual

Browse online or download Owner's Manual for Gate Opener DoorKing 6003. DoorKing 6003 Owner`s manual [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
CAUTION
7”
7”
RED 24V RED
BLK 115V WHT
QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6003 - FOR A GATE UP TO 10 FEET, 300LBS AND “OPENING TO THE INSIDE”
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
115 VAC Connection
Battery Connection
40.5” Fixed Position
Mounting System and Adjusting Open/Close Position
90°
A support
bar must be
installed the
entire length
of the gate
to support
the pickets.
Securely mount control box
near the actuator arm with
appropriate hardware
(not supplied).
Gate Hinge Pivot Point
1. Brown
2. Blue
3. Orange
4. Red
5. Yellow
6. Green
7. Green/White
Actuator
Cable
Loop Wires
Coaxial Cable Antenna
(Not Supplied)
Coaxial
Cable
Antenna
Actuator
Cable
Power Conduit
Loops Conduit
Alarm
Reset
Com
Com
4 Open Input
5 Open Input
N.O.
Relay
24V
Chassis
Ground
Mounting
Hole
Front Bracket Pivot Point
Front Bracket
Rear Bracket
(Adjustable, See Manual)
Rear Bracket Pivot Point
Radio Receiver
Tip: It is recommended
that a surge suppressor
be installed on the high
voltage power lines.
Manual Key Release
C
C
A
B
G
F
C
C
Not included - Refer to the Wiring/Owner’s
manual and Loop Information Manual
(available free from www.dkaccess.com) for
more information.
E
E
Do not connect the battery to the circuit
board until power is needed to test the
actuator arm.
H
H
KEY SWITCH BUTTON: Cycles operator when pressed.
I
I
RESET BUTTON: Resets circuit board.
Closed Position
Open to
the Inside
Position
Control Box
1
7
6
5
4
3
2
Actuator arm and brackets MUST be level!
CONTROL BOX MUST BE
PROPERLY GROUNDED!!
6003-066-L-1-13
Copyright 2013 DoorKing, Inc. All rights reserved.
OPEN
CLOSE
Mounting Holes
9410
9409
4302
D
D
12 V
3 Amp/Hr
Battery
12 V
3 Amp/Hr
Battery
G
J
J
Limit
Slow Down
Unscrew 4 screws to remove cover.
Loosen nut to adjust limit sensor.
t
t
Note: To turn-off ALL power to the operator, the AC
power switch must be turned off and the battery
plug must be disconnected from the circuit board.
Note: This illustration shows
NO gate hinge inset. If gate
hinge is inset on wall, see
“Rear Bracket Configurations
for Different Gate Hinge Insets”
in the Actuator Arm and Control
Box Mounting manual.
Limit Sensors
Circuit board power
must be on to adjust
limit sensors, LEDs
will light.
123
A
B
1. Direction Primary operator opens.
2. OFF
3. OFF
4. ON Auto-Close Timer
5. ON - Shadow Loop
6. OFF
7. OFF
8. OFF
Adjust 1 to 23 sec.
Cut Off Excess Bracket
Cut Off Excess Bracket
Bottom
Middle
Top
Coaxial Cable Antenna Kit
P/N 1514-073 (Sold separately)
1. ON - Relay for Dual Plug-In Shadow Loop
2. OFF - Relay for Dual Plug-In Shadow Loop
3. OFF
4. OFF
SW 1
1
ON
2 3 4 5 6 7 8
SW 2
1
ON
2 3 4
Typical Settings for Single Operator with Plug-In Loops
Plug-In Loop Detectors
Circuit Board Settings
Single Channel Exit
Plug-In Loop Detector
Dual Channel
Reverse and Shadow
Plug-In Loop Detector
Battery Plug
AC Power Switch
Relay must be set
to N.O. for shadow
loop.
NC
NO
Loop
Jumper
To #11
To #8
DANGER
HIGH VOLTAGE!
F
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Low Voltage
Tip: Never run low voltage
rated wire insulation in the
same conduit as high voltage
rated wire insulation. Keep
them in separate conduits.
High Voltage
Wire Size Distance
14 AWG
12 AWG
Up to 200 ft
Beyond 200 ft
115 VAC Input
Power Wire
#8 - #11 Shadow Loop Output
DO NOT cycle operator before limit sensors
and DIP-switches have been adjusted,
damage could occur to gate and operator.
Please refer to the Wiring/Owner’s manual.
Model 115 VAC 6003 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the
6003 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.
SINGLE/PRIMARY
Actuator Cable
Circuit Board
Connection
DO NOT connect the
Primary operator to
this connection.
Connect Secondary
operator ONLY.
Do not install the actuator arm in
fully extended (Bottomed out)
position. This will damage the arm
(See Actuator Arm and Control
Box Mounting manual for more
information).
See reverse side.
Note: Please refer to the
Wiring/Owner’s manual for
more information.
Not included - Refer to a specific Radio
Receiver Manual (available from
www.dkaccess.com) for more information on
radio receivers and antenna installation. See
reverse side for wiring.
3 Limit
5 Limit
4 Slo Dwn
6 Slo Dwn
Page view 0
1 2

Summary of Contents

Page 1 - HIGH VOLTAGE!

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CAUTION7”7”RED 24V REDBLK 115V WHT QUICKSTART “BASIC” GUIDELINES FOR MODEL 11

Page 2 - Main Terminal

OFFOpeningDirection ofSECONDARYOperator23Terminal #4 is output from plug-in exit loop detector installed in EXIT loop port.Same opening directions as