DoorKing 1812 Classic Owner's Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
MIC
VOL
FB1
FB2
MASTER
CODE
ON
1871-010
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
EARTH
GND
SW1
ENTRY BY-PASS
1875-010
1
CENTRAL
OFFICE
PHONE
IN
PHONE
OUT
HOME
2345678
TIP
TIP
TIP
RING
RING
RING
TIP
RING
18
17
16
Com
15 N.C.
14 N.O.
13 Com
12 N.C.
11 N.O.
10
9
8
7
6
5
RING
4 TIP
3 GND
2 TIP
1 RING
24
VAC
It is highly recommended that you consult the Installation/Owner’s manual for complete wiring instructions on all the different types of installations and programming.
By-Pass Board
Basic Programming for the 1812 Classic
Programming Momentary Access Codes
Control Board
The 1812 Classic has been programmed at the factory with many of the programming parameters (default setting) set for a
typical residential application with a single 1812 Classic.
However, you must program a “Master Code” before putting the 1812 Classic into service. If you are
using more than a single 1812 Classic in the system, or if you are using any of the advanced features of the 1812 Classic,
such as Time Zones, Do-Not-Disturb Schedules, Call Forwarding, Holiday Schedules, Hold Open Schedules, Directory Code
Dial-Out Phone Numbers, Temporary Access Codes, etc., you will need to download the complete Installation/Owner’s and
Programming Manual from our tech support web site.
Programming Relay 1 and 2 Strike Time - (Factory default is 1 second)
1. Press
*
0 3 and enter the MASTER CODE. [
*
0 3 _ _ _ _ (beep)]
2. Enter “1” for relay 1 or “2” for relay 2, then press
*
. [ _
*
(beep)]
3. Enter a two-digit strike time (00-99), then press
*
. [ _ _
*
(beep)]
Note: Strike time entered in seconds. 00 = ¼ sec., 10 = 10 seconds, etc.
4. Repeat steps 2 and 3 to set the other relay strike time if necessary.
5. Press “0 #” TOGETHER to end. [0 # (beeeeeep)]
This “Quickstart” guideline is designed for installing a single 1812
Classic in a typical single family home application using the factory
default settings programmed in the 1812 Classic. Complete
installation instructions and programming manual is available on the
enclosed CD AND from our tech support web site.
CLICK HERE TO VISIT DOORKING’S TECHNICAL WEB SITE:
www.dkaccess.com/english/Telephone_Entry/telephone_entry.html.
1. Turn Master Code switch ON.
2. Enter a four digit Master Code number
then press “
*
”, “beep” will be heard.
[ _ _ _ _ (beep)] (Write down master code).
3. Turn Master Code switch OFF.
Switch OFF - Normal operating mode positon (position shown).
Switch ON - After master code switch has been turned ON, system
will be in Master Code programming mode. (If master code switch
is turned ON and master code is not entered, the system will
sound a short tone after 30 seconds and continue every 30
seconds until master code is entered or switch is turned off).
Master Code Switch Description
“Normally Open”
Vehicular
Gate Operator
(Terminal 11 and 13)
INPUT
PHONE LINE
TIP RING
1877-010
OUTPUT
TIP RING GND GND
LOW VOLTAGE LINE
OUTOUT
1878-010
ININGNDGND
INPUT
OUTPUT
Locate Homeowner’s
Phone Line Inside Device
To “Existing”
Alarm Control Panel
“Existing” Alarm System
Phone
Jack
Phone
Jack
Cat5e Cat5e
Cat5e Without Surge Board
Without
Surge
Board
Central Office (C.O.)
Demarcation Device
Cat5e
Cat5e
Recommended
Recommended
Recommended
Cat5e
Ground 12 AWG Min.
Ground 12 AWG Min.
Within 3 ft of Board
Ground 12 AWG Min.
Within 3 ft of Board
Ground 12 AWG Min.
Phone at
Home #12
Phone at
Home #11
Phone at
Home #13
Tip
Ring
Tip
Ring
Tip
Ring
Homeowner’s Phone(s)
“Normally Close” Pedestrian Gate/Door with Maglock
(Terminal 15 and 16)
“Normally Open” Pedestrian Gate/Door with Electric Strike
(Terminal 14 and 16)
Maglock
Electric
Strike
W
A
R
NING
M
O
V
I
N
G
G
A
TE
C
A
N
C
A
U
S
E
O
p
e
r
a
t
e
g
a
t
e
o
n
l
y
w
h
en
g
a
t
e
ar
ea
i
s
i
n
s
i
g
h
t
and
f
r
e
e
o
f
p
eo
p
l
e
a
n
d
o
b
st
r
u
c
t
i
o
n
s.
D
o
n
o
t
a
l
l
o
w
c
h
i
l
d
r
e
n
t
o
p
l
a
y
i
n
g
at
e
ar
e
a
o
r
o
p
er
at
e
g
a
t
e
.
D
o
n
o
t
s
t
a
n
d
i
n
g
at
e
p
a
t
h
o
r
w
a
l
k
t
h
r
o
u
g
h
p
a
t
h
w
h
i
l
e
g
a
t
e
i
s
m
o
v
i
n
g
.
R
e
a
d
o
w
n
e
r
s
m
a
n
u
a
l
a
n
d
s
af
e
t
y
i
n
s
t
r
u
c
t
i
o
n
s
.
S
E
RIOUS
I
N
J
U
R
Y
O
R D
E
A
T
H
C
L
A
S
S
C
E
R
T
I
F
I
E
D
T
O
C
A
N
/
C
S
A
C
2
2
.
2
N
O
.
2
4
7
C
ON
FOR
M
S
T
O
A
N
S
I
/U
L
-
3
2
5
V
E
H
I
C
U
LA
R
G
A
TE
O
P
E
R
A
TO
R
H
P
5
3
3
8
2
M
O
D
E
L
S
E
R
I
A
L
V
OL
T
S
P
H
A
S
E
A
M
P
S
6
0
H
z
M
A
X
G
A
T
E
L
O
A
D
D
o
o
r
K
i
n
g
,
I
n
c
.
,
I
n
g
l
e
w
o
o
d
,
C
A
TIP (
+
):
White/blue mark
RING (-):
Blue/white mark
Magnetic locks or electric strikes must be powered from a
separate UL Listed power transformer. DO NOT power electric
strikes or magnetic locks from the 1812 Classic power
transformer. keep power wire runs as short as possible.
Adjust feedback from phone lines if necessary.
Refer to Installation/Owner’s manual for more
information.
Use common electrical safety practices when connecting
telephone wires. You can receive a substantial jolt if the
phone rings while handling these wires.“RING” terminal
voltage varies and can be between -48 to -130 Volts AC,
depending on the distance to the central office.“TIP”
terminal is always positive with respect to RING terminal.
The By-Pass board is required.
Phone Line Surge Suppressor
Optional P/N 1877-010
Low Voltage
Surge Suppressor
Optional P/N 1878-010
Separate UL
Listed Power
Transformer
Check Polarity of Telephone Line
Check for polarity on the incoming telephone line to each board and maintain polarity
throughout the telephone line (TIP (+), RING (-).
Cat5e Gel Filled (flooded) UV resistant direct burial cable run in conduit recommended.
DO NOT run telephone wires in the same conduit as high voltage AC wire.
Main
Terminal
TIP
Older Lines
Green Wire (+)
Older Lines
Red Wire (-)
RING
Ground
Ground
Ground
Ground
Phone In
(1-2)
MAS
MAS
CO
Relay 1
(11-13)
SPEAKER
VOL
MIC VOL
Do Not Adjust
Resident Phone Line Feedback
Outside Phone Line Feedback
Wire Size Max Distance
24 AWG
22 AWG
20 AWG
18 AWG
800 ft
1600 ft
2200 ft
3600 ft
Telephone Wire Run (Cat5e) Table
Wire Size Max Distance
18 AWG
16 AWG
100 ft
200 ft
24 VAC Power Transformer and
Access Control Device(s)
Wire Run Table
Supplied 24 VAC Power
Transformer
Polarity does not matter.
Programming the “Master Code”
Program MASTER CODE
Access Control Devices
RJ31x
Phone Jack
installed
Before 1812
System
Telephone Company
Demarcation Point
Complete Instructions
Programming Momentary Access Code(s) to Operate Relay 1 and/or 2 on a 24/7 Basis - (Maximum of 14 codes per relay)
1. Press
*
0 2 and enter the MASTER CODE. [
*
0 2 _ _ _ _ (beep)]
2. Enter a two-digit “location code” to determine which relay will be activated, (01-14) - relay 1’s location OR (26-39) - relay 2’s location, then press
*
. [ _ _
*
(beep)]
3. Choose and enter a four-digit momentary access code, then press
*
. [ _ _ _ _
*
(beep)]
4. Repeat steps 2 and 3 to enter additional momentary access codes for each relay, do not duplicate or go beyond “location code” number limits for each relay.
5. Press “0 #” TOGETHER to end programming. [0 # (beeeeeep)]
Cat5 Wire
Four Conductor
Wire
Tip (+)
1st Line
Wire
Conversion
2nd Line
3rd Line
4th Line
Green
Red
Black
Yellow
Blue Pair
Orange Pair
Green Pair
Brown Pair
Ring (-)
(+) Tip
(-) Ring
(+) Tip
(-) Ring
(+) Tip
(-) Ring
Older
Residential
Homes
Modern
Residential
Homes
Phone Wiring
Basics “101”
Relay 2
(14-16)
Power
(17-18)
Phone Out
(4-5)
IMPORTANT All boards
MUST be properly
grounded or the system
will NOT function correctly!
Orange Pair
Orange
Pair
Green
Pair
Green Pair
Note: Each relay can control a
normally open OR normally close
access control device. Relay
contacts are rated for 3 amps @
30 VAC maximum.
Output
24 VAC
20 VA
QUICKSTART “BASIC” WIRING GUIDELINES FOR AN 1812 CLASSIC SYSTEM WITH TWO ACCESS CONTROL DEVICES
Copyright 2010 DoorKing, Inc. All rights reserved.
1812-163-G-10-10
Page view 1
1 2

Comments to this Manuals

No comments